JK-90B 270L Salt Spray Testing Chamber Salt Spray Tester 110V 2000W

★★★★★ 4.9 56 reviews

US$1,199.60
Price when purchased online
Free shipping Free 30-day returns

Sold and shipped by guria.ge
We aim to show you accurate product information. Manufacturers, suppliers and others provide what you see here.
US$1,199.60
Price when purchased online
Free shipping Free 30-day returns

How do you want your item?
You get 30 days free! Choose a plan at checkout.
Shipping
Arrives Sep 5
Free
Pickup
Check nearby
Delivery
Not available

Sold and shipped by guria.ge
Free 30-day returns Details

Product details

Management number 237908183 Release Date 2026/07/11 List Price US$1,199.60 Model Number 237908183
Category

<p>Parameter:<br>Voltage: 110V<br>Power: 2000W<br>Laboratory volume: 270L<br>Inner size: 900*600*400mm<br>Outer size: 1390*830*1100mm<br>Spray method: continuous</p> <p>Note:<br>Please note that control panels with different colors are shipped randomly.</p> <p>Application:<br>It's used to test the corrosion resistance ofthe electrodeposited coating of many kinds of metallic materials. Use thesalt spray test machine to spray the Sodium Chloride Solution to thesurface of electric coating to achieve the purpose of detection. Thematerial is stainless steel.</p> <p>Equipment:<br>All equipmentneeded in the test: Spray nozzle, salt water barrel, test piece support, spray liquid collection container, test chamber, salt water, supplytank, pressure tank, supply equipment and exhaust equipment required forcompressed air, the device is shown in the figure, and the test is conducted as follow.<br>Bluntmaterial is required, it is required that the material itself cannot becorroded, and it can not affect the corrosion test.<br>Thefog nozzle cannot spray the test liquid directly to the sample, thesolution at the top of the spraying chamber cannot drop on the testpiece.<br>Thetest liquid dropping from test piece cannot flow back to the salt bucketagain for the test.<br>Thesolution should not contain grease and dust, so you have to prepare anair cleaner.<br>Sprayliquid should be collected for at least 16 hours, and the average of the solution collected in one hour is 1-2ml. Use the final average to represent theamount of spray.<br>Theconcentration of the Sodium Chloride Solution should be maintainedat 40~60g/L.<br>Thetemperature of the pressure barrel should be kept in 47+1 DEG C,temperature of the salt water barrel should be kept in 35+1 DEG C.<br>Sample Placement: If you need to test many pieces,make sure that all major surfaces can be detected by salt fog at thesame time.<br>Arrangement of samples, the sprayshould be free to drop on all the test pieces, preventing the situationof blocking the spray.<br>Each sample cannot be in contactwith each other.<br>Salt spray can’t drop from one testpiece to another one.<br>Sample identification mark should bemarked at the bottom of the test piece.</p> <p>Description:<br>Spray method:<br>Adopting bernoute principle to absorb brine and then atomize brine, the degree of atomization is even, no blocking phenomenon of crystallization, can ensure the standard of continuous test.<br>Nozzles: made of special glass nozzles, the size of the spray can be adjusted.<br>Spray flow rate adjustment 1-2ml (ml/8ocm'/nh) (16-hour average)<br>Spray mode: continuous type<br>Adopt the direct heating method, the heating speed is fast to reduce the standby time, when the temperature reaches ON. OFF switching is conducted, accurate temperature, less power consumption.(heating tube is made of high corrosion resistance heating system: titanium tube).</p> <p>Meet the standard:<br>GB/T 2423. 17-1993 Salt spray test<br>GB/T 2423. 18-2000 Salt spray test<br>GB/T 10125-1997 Salt spray test<br>IEC68-2-52 1996 Salt spray test<br>ASTM. B117-97 Salt spray test<br>GB. 10587-89 Salt spray test<br>IEC68-2-11 Salt spray test<br>JIS H8502 Salt spray test<br>CNS. 4158 Salt spray test<br>CNS. 4159 CASS Accelerate the spray test of cupric acetate<br>GB/T 12967.3-91 CASS Accelerate the spray test of cupric acetate<br>GB/T 1771-2007 Neutral salt spray performance test of paints and varnishes</p> <p>Items Include:239165<br>Salt spray testing chamber 110V</p>

  • The spray nozzle is atomized by absorbing salt water according to the Bernoult principle, and no crystal salt is produced.
  • Power outage memory function.Dual over temperature protection, designed and functional in accordance with international standards.
  • According to the international salt spray test operation requirements, the fully automatic mode and manual mode can be freely selected.
  • The control system is equipped with touchscreen button settings, and the LCD control operation interface is all on the same board. Humanized upright operation ensures that all detection data is clear at a glance.
  • Continuous spray. Fully automatic programming operation, one write, no need for attendance.
Brand Banfluxion
Model 239165-BanY
Weight 743 lb

Correction of product information

If you notice any omissions or errors in the product information on this page, please use the correction request form below.

Correction Request Form

Customer ratings & reviews

4.9 out of 5
★★★★★
56 ratings | 23 reviews
How item rating is calculated
View all reviews
5 stars
89% (50)
4 stars
1% (1)
3 stars
0% (0)
2 stars
0% (0)
1 star
10% (6)
Sort by

There are currently no written reviews for this product.